SAMSUNG CAC FLOOR CONSOLE COMPLETE SYSTEM 5KW R32

Product Code: CONSOLE5KIT | Availability: Available to Backorder

Samsung CAC Floor Console Complete System 5kW R32

Click to enlarge image

Product Description

This Samsung Floor Console 5.0kW Air Conditioning System includes:


1 x AC052RXADKG/EU - 5.0kW Outdoor Single Phase Inverter Heat Pump

1 x AC052RNJDKG/EU - 5.0kW Indoor Console Floor Standing Unit

1 x MR-EH01 - Infra-Red Handheld Controller


The Samsung Floor Mounted Console provides optimal performance with an elegant and compact design.


2-Way Air Outlets

By having two separate air outlets for cooling and heating, the Console unit ensures that every inch of space achieves the desired temperature. Warm air is expelled from the bottom air outlet, helping to spread warmth evenly throughout the room. With these innovative 2-way air outlets, businesses are able to enjoy a more comfortable, pleasant environment.


WiFi Control

Temperatures in your building can be managed remotely using the SmartThings App. Turning it on and off, selecting the cooling mode, scheduling its operation or monitoring the power consumption is just one touch away. The Bixby 2.0 Artificial Intelligence (AI) system analyses and predicts your needs so it can suggest the best settings for inside your home.

Electrical

Power Supply (Outdoor): 1Φ, 220–240 V, 50 Hz

Power Supply (Indoor): 1Φ, 220–240 V, 50 Hz

MCA (System - Outdoor/Indoor): 17.5 (16.5 / 1.0) A

MFA (System): 20.6 A

Minimum SSC Value (Outdoor): Not Applicable

Interconnecting Communication Cable: Screened 0.75–1.5 mm², 2 Core, F1 F2 Connection


Performance

Nominal Cooling Capacity (Total / Sensible): 5.0 kW (3.4 kW)

UK Cooling Capacity (Total / Sensible): 4.8 kW (3.3 kW)

Nominal Heating Capacity: 5.6 kW

Operating Temperature Range (Cooling): -15.0 ~ 50.0 °C

Operating Temperature Range (Heating): -20.0 ~ 24.0 °C


Energy Efficiency

EER (Nominal Cooling): 2.79 W/W

COP (Nominal Heating): 3.01 W/W

Seasonal Efficiency (SEER / Energy Label): 5.9 W/W / A+

SCOP / Energy Label: 4.0 W/W / A+


Air Flow Rate

Indoor Unit Airflow Rate (H/M/L): 157 / 140 / 123 L/s

Outdoor Unit Airflow Rate: 667 L/s


Piping Connections

Liquid Pipe: 6.35 mm (1/4")

Gas Pipe: 12.7 mm (1/2")

Drain Pipe: ID 18 mm Hose

Max Piping Length (Height): 30 m (20 m)


Refrigerant

Type: R32 (Fluorinated greenhouse gas, GWP=675)

Factory Charging: 1.2 kg

tCO₂e: 0.81

Precharge to: 10 m

Additional Charge: 15 g/m


Sound

Indoor Sound Pressure Level (H/M/L): 43 / 39 / 35 dB(A)

Indoor Sound Power Level: 61 dB(A)

Outdoor Sound Pressure Level (Cooling / Heating): 48 / 48 dB(A)

Outdoor Sound Power Level: 62 dB(A)


Dimensions

Net Weight (Indoor Unit / Outdoor Unit): 16.0 / 43.0 kg

Indoor Unit Net Dimensions (W x H x D): 720 x 620 x 199 mm

Outdoor Unit Net Dimensions (W x H x D): 880 x 638 x 310 mm

Product Spec Sheets

 Delivery Terms

Orders over £150 qualify for FREE NEXT DAY delivery*. Orders under £150 may be subject to a carriage charge. Please see below for our delivery options.

We offer several different delivery services. Please see below for our delivery options.

*Please note that orders including oversized items or to the Isle of Wight, the Isle of Man, the Scottish Isles, the Scottish Highlands, Northern Ireland and the Channel Isles will incur a carriage surcharge.

Orders placed before 16:00 with next working day/timed services will be dispatched the same day (Monday to Friday). Orders placed after 16:00 will not be dispatched until the next working day. Orders placed on Saturdays, Sundays, or bank holidays will be dispatched on the next working day. "Next working day" means Monday to Friday, excluding bank holidays. Orders placed with any of the services below will not be delivered on a Saturday or Sunday.

We aim to despatch all orders with standard services within two working days, as long as all items are in stock. 

 

Delivery Services

We offer the following delivery services:

  • FREE Local same day - Within a 15-mile radius of RG14 2EZ, when ordered before 13:00.
  • FREE Local next working day - Within a 15-mile radius of RG14 2EZ, when ordered before 16:00.
  • Standard 2-3 working days
  • Express next working day - When ordered before 16:00
  • Next working day by 12:00 - When ordered before 16:00
  • Next working day by 10:30 - When ordered before 16:00

 

Collection

All orders are available for collection from our stores. Collection orders will typically be ready within 2 hours of the order being placed as long as all items are in stock at the time of order.

At Connect ACR Supplies, we aim to deal with returns fairly and efficiently. As a business-to-business supplier, returns are accepted in line with our Terms and Conditions of Sale and are subject to the type of product being returned and its condition on arrival.

Please include your order number, the items you wish to return, and the reason for the return.

Stock Items

Standard stock lines may, at our discretion, be accepted for credit where they are returned in a resaleable condition. To be eligible, goods must be:

  • complete and unused

  • in their original packaging, where applicable

  • supplied with all accessories, manuals, labels, and components

  • free from damage, markings, labels, or signs of installation


There is no fixed timeframe for the return of standard stock items, provided the product remains a current stock line at the time of return.

Return Carriage

The customer is responsible for arranging and paying for return transport. Goods remain the customer's responsibility until they have been physically received and signed for by Connect ACR Supplies. We recommend using a tracked service and ensuring all items are packaged securely.

Non-Stock and Special Order Items

Non-stock, specially ordered, configured, or otherwise special items can only be returned if our supplier agrees to accept them. Any supplier restocking charges, handling charges, or carriage costs will be deducted from the credit where applicable. Credit for these items is not guaranteed.

Non-Returnable Items

Unless faulty, the following items are not eligible for return:

  • custom-made products

  • cut-to-length materials

  • items that have been installed, powered, used, or commissioned

  • sealed items where the seal has been broken

  • software or licences

  • any item marked as non-returnable on the quotation or order acknowledgement
     

Refrigerants, Cylinders and Hazardous Goods

Returns involving refrigerants, pressurised cylinders, or other hazardous goods are subject to relevant transport and compliance requirements. Opened or partially used refrigerant will not be accepted for credit. Cylinder returns must follow our documented returns procedure. Additional charges may apply where cylinders are returned incorrectly or in a non-compliant manner.

Faulty Goods

If you believe goods are faulty, please contact us before returning them. Returned items may be inspected and tested. If no fault is found, or the issue is due to misuse, incorrect installation, or another exclusion under our Terms, we may return the goods and apply reasonable inspection, testing, and carriage charges.

Credits and Refunds

For eligible returns, credit will be raised for the net value of the goods less any applicable deductions. For special or non-stock items, credit may not be processed until supplier acceptance and, where applicable, supplier credit has been received.

ADD FAVOURITE

Please Log in or Sign up to add this product to your Favourite List.

Low Stock Warning

This product is low on stock and therefore may take longer to arrive, you can still order this product by closing this popup (using the x above) and adding your item to the basket again.

Important Notice

Please Note
We currently have a complete power failure, please send e-mails for enquiries and we will respond once power is back up and running - this has also affected our telephone lines